WATREET – FOOD GRADE COOLING TOWER WATER TREATMENT CHEMICALS

Industrial cooling systems are required to function smoothly. Therefore, it is essential that correct cooling water conditions are established and maintained at all times. To ensure cooling systems are correctly maintained and operate at optimum efficiency it is essential to carefully select cooling water treatment chemicals. Our comprehensive range of high-performance cooling water treatment chemicals has been scientifically formulated to deliver significant operational benefits and performance improvements to cooling systems that use water as a primary coolant. Our wide range of formulations helps to minimize scale, corrosion, fouling, and biofouling to ensure trouble-free operation of the system.

COOLING TOWER MULTIPURPOSE: SCALE, CORROSION INHIBITOR AND DISPERSANTS 

Our multipurpose organic corrosion and scale inhibitor is designed for use in industrial cooling systems. It is composed of ingredients that are biodegradable and contain no zinc or heavy metal components. It functions by forming a microscopic inhibitive film on the metal surface that acts as a barrier to prevent or minimize corrosion. It also contains effective polymeric antifoulants and sequestrants to help remove metallic oxide, silt, and dead microbiological material to maintain a cleaner and more efficient operating system.

Product Range

  • WT2000                For Low TDS System      
  • WT2870                For High TDS System     
  • WT2890                For High Corrosive System          

COOLING TOWER SCALE / CORROSION INHIBITORS (CARBONATE, SULPHATE & SILICA INHIBITOR).     

The unwanted accumulation of scale and detrimental impact of metallic corrosion can be significant issues that affect the operation and maintenance of open and closed cooling water systems. To ensure that such open and closed cooling systems are well maintained and operate at optimum efficiency, it is essential that the correct water conditions are maintained at all times. This can be achieved using carefully selected scale and corrosion inhibitors designed specifically for such cooling systems. Our technologically advanced cooling water scale and corrosion inhibitors have been scientifically formulated to protect cooling systems from the effects of both scale build-up and metallic corrosion in a single product.

Product Range

  • WTD100               For Low TDS System
  • WTD200               For High TDS System     

COOLING TOWER CORROSION INHIBITORS

The detrimental impact of metallic corrosion can be a significant issue that affects the operation and maintenance of open and closed cooling water systems. To ensure that such closed cooling systems are well maintained and operate at optimum efficiency it is essential that the correct water conditions are maintained at all times. This can be achieved using carefully selected corrosion inhibitors designed specifically for cooling systems. Our advanced technology cooling water corrosion inhibitors have been scientifically formulated to protect cooling systems from the effects of metallic corrosion. Our high-performance corrosion inhibitors deliver improved system performance, helping to reduce maintenance costs, improve reliability and optimise operational efficiency.

Product Range

  • WTCR100             For Closed System (Chilling Plants)          
  • WTCR200 (P*)   For Closed System (Chilling Plants)          

COOLING TOWER DISPERSANTS      

The accumulation of microbiological slimes, biofilm and general bio-fouling in cooling water systems reduces system efficiency, increases operating and maintenance costs, and raises risks to safety and health. Our polymeric dispersant is a synthetic organic anti-foulant which inhibits the deposition of fouling materials on the heat transfer surfaces. It eliminates fouling caused by dead microbiological growth, phosphates, silicates, metallic oxides silt and other air-borne materials. Thus, it keeps surfaces clean, maintains a high rate of heat transfer and aids the formation of corrosion inhibitor film.

Product Range

  • WTA100               Organic Anti-Foulant     

COOLING TOWER BIO DISPERSANT 

The accumulation of microbiological slimes, biofilm and general bio-fouling in cooling water systems reduces system efficiency, increases operating and maintenance costs. If ignored leads to under deposit and pitting type of corrosion. Our synthetic organic Bio dispersant is effective in removing dead algal and slime mass from cooling system. It has a capacity to penetrate inside the thick algae mats on the cooling tower deck or fills and help the biocide to penetrate the biomass. It also has a deterrent effect and it cleans the system on line. Generally, it is dosed prior to biocide or along with biocide to enhance its efficacy:

Product Range

  • WTA200 To Prevent Biofouling 

COOLING TOWER BIOCIDES 

The control of microbiological activity is an important, often safety critical activity in many commercial, manufacturing and industrial process applications. Our biocides are effective in controlling bacterial slime and fungal growth in industrial recirculating cooling water systems, air washer systems and evaporate condensers. We have a range of both oxidizing and nonoxidizing biocides, which have a broad-spectrum efficacy and are effective over a wide range of pH.

Product Range

  • WTB101 Quaternary Ammonium Based (BKC)    
  • WTB201 Carbamate Based          
  • WTB660 Chlorine Based
  • WTB700 Nano Silver & Hydrogen Peroxide Based
  • WTB900 Isothiozoline Based      
  • WTB1100 Quaternary Ammonium Based (DDAC)              
  • WTB1200 Bronopol Based Bactericide    
  • WTB1300 Isothiozoline Based (Large System)     
  • WTB1900 Triazine Based Algaecide         

COOLING TOWER ON LINE CLEANER

Our cleaning system has been specially developed to effectively remove deposit, sludge / foulants from the system. It is a blend of specific chelating agents designed for removal of Iron, Calcium and Magnesium based deposits from cooling water systems where it is not practical to remove the tower packing. It is found to be most effective in cleaning, where deposition or oil contamination is suspected of reducing heat transfer or restricting flow available. Deposits are softened and solubilized as our cleaner penetrates the deposits and enhances the action of cooling water dispersants to slough off remaining deposits which are later removed during a blow down or draining.

Product Range

  • WT1153A and WT1153B Closed System Chemical De-Scalant & Polymeric Dispersant (Should be used in combination)
  • WTIC305 and WTIC315 Open System Chemical De-Scalant & Polymeric Dispersant (Should be used in combination)